Problem

The following error is returned when trying to access a TestTrack Server in a Novell Network.

MM-DD-YY HH:MM:SS PM: SERVER-4.11-679 Station x record lock threshold exceeded. Total violations #####.

The error may also include the following line:
Severity = 0 Locus = 11 Class = 19

Cause

The Maximum File Locks Per Connection = number parameter may be set with too low of a value. This parameter controls how many record locks the operating system can handle. The default value is 250. On average, TestTrack has 100 files locked into memory per database.

Solution

Increase the number of locked files to the maximum allowed. See the following article in the Novell Knowledgebase for more information: Explanation of Maximum File and Record Locks.