document Expanding and Collapsing Tree Nodes in Scripts
If you expand and collapse nodes to select an item in a tree control during recording, a Select statement is added to the script. This statement includes all of the nodes that were expanded or collapsed to select the item. The following example shows a Select statement that selects an item in...
23 Dec, 2014
document Cannot Connect to a Global Repository Hosted on Windows Vista
Problem If the QA Wizard Pro global repository server is hosted on Windows Vista and the server computer is locked, computers connected to the global repository are disconnected after a period of time. QA Wizard Pro cannot reconnect to the global repository server, even after clicking the...
23 Dec, 2014
document Differentiating Applications with the Same Name in Application Repositories
Problem The following warning is displayed when running a QA Wizard Pro script: 'Local and global repository entries were found for 'application name'. The local repository was used.' Cause The application the script accesses has the same name in the local and global application...
23 Dec, 2014
document QA Wizard Pro 2007.3.3 and Earlier Does Not Run on Windows Vista
You cannot use QA Wizard Pro 2007.3.3 and earlier on Windows Vista because the digital signatures will be expired. The following error is returned when you start QA Wizard Pro: 'A referral was returned from the server.' To use QA Wizard Pro on Windows Vista, you must upgrade to QA...
20 Mar, 2015
document QA Wizard Pro Ports
QA Wizard Pro communicates via TCP/IP using the following default port numbers. You can change the port for security reasons or if another application uses it. QA Wizard Pro Server Communicates with the global application repository and status tool Default port: 8002 To change the...
23 Dec, 2014
document Upgrades Fail on Computers Running AVG 9.0
There are known issues when upgrading QA Wizard Pro on computers running AVG 9.0. Before you upgrade, disable AVG 9.0 and then re-enable it after the upgrade is completed.
23 Dec, 2014
document 611 Error When Testing Applications Using Microsoft Active Accessibility
Problem The following error is returned when recording QA Wizard Pro scripts or populating the application repository for applications that use Microsoft Active Accessibility: 'Error communicating with the target application: [611].' Cause A known Visual Basic 6 issue occurs when an...
23 Dec, 2014
document Using Multiple Applications in a Script
You can use more than one application or running process to perform steps in a single QA Wizard Pro script. For example, if a script tests an application that generates output, you may want to add the output to another application before the script finishes. You can use script control statements...
29 Dec, 2014
document 1053 Error When Starting the Global Repository Service
Problem The following error is returned when starting the QA Wizard Pro global repository service (QAWRepository.exe or QAWServer.exe) on Windows Server 2003 or Windows Server 2008: 'Error 1053: The service did not respond to the start or control request in a timely...
23 Dec, 2014
document QtCoreSeapineTT4.dll Error When Starting QA Wizard Pro
Note: The following information only applies to QA Wizard Pro 2011.1.x and TestTrack 2011.1.x. Problem After upgrading to QA Wizard Pro and TestTrack 2011.1.x, the following error is returned when starting QA Wizard Pro: 'Program cannot start because QtCoreSeapineTT4.dll on the computer...