Search the Knowledgebase |
Browse by Category |
|
|
|
View Articles by Category |
|
There are no sub categories
|
QA Wizard Pro
|
|
|
(Page 1 of 5)
«« |
Prev |
1 |
2 |
3 |
4 |
5 |
Next |
»»
|
There were 86 articles found in this category:
Seapine ALM Reporting Platform ERDs
ALM Reporting Platform 2012.1 ERD ALM Reporting Platform 2012.0 ERD ALM Reporting Platform 2011.1 ERD ALM Reporting Platform 2011.0 ERD
Seapine ALM Reporting Platform Compatibility
Following are the supported QA Wizard Pro, Seapine License Server, Surround SCM, and TestTrack versions for each ALM Reporting Platform version. ALM Reporting Platform 2012.1 QA Wizard Pro 2011.1 - 2012.1 Seapine License Server 2011.1 - 2012.1 Surround SCM 2011.0 - 2012.1 TestTrack 2011.0 - 20 ...
Seapine ALM Reporting Platform System Requirements
Operating system The current version of the reporting platform is supported on Microsoft Windows XP, Server 2003, Vista, Server 2008, and Windows 7. RDBMS support The reporting platform database is stored in a Relational Database Management System (RDBMS). Following are the supported platforms ...
QA Wizard Pro Server Database ERDs
QA Wizard Pro 2012.1 ERD QA Wizard Pro 2012.0 ERD QA Wizard Pro 2011.1 ERD
QA Wizard Pro System Requirements
QA Wizard Pro system requirements differ based on whether the computer is used to record or run scripts. A computer that meets the minimum requirements for recording scripts can also run scripts. The following requirements are intended to be used in combination with the hardware requirements ...
QA Wizard Pro Google Chrome Support
This article explains limitations for testing applications in Google Chrome with QA Wizard Pro. Google Chrome unsupported features The following Chrome features cannot be tested with QA Wizard Pro. Bookmarks bar, including buttons and popup menus in the bar Incognito mode (private browsing) PD ...
QA Wizard Pro Server System Recommendations
The attached PDF file includes the system recommendations for running the QA Wizard Pro server application. These are not minimum requirements—they are the recommended system configurations for optimal global repository performance.
QA Wizard Pro Supported Technologies
The following technologies are supported and tested. For a list of supported controls, see Appendix A in the QA Wizard Pro User Guide. .NET Windows Forms 1.1, 2.0, 3.0, 3.5, 4.0 .NET WPF 3.0, 3.5, 4.0 Adobe Flash 9, 10, 11 Adobe Flex (SDK) 3.x, 4.x ComponentOne Studio for WinForms 2006.2 - ...
QA Wizard Pro Ports
QA Wizard Pro communicates via TCP/IP using the following default port numbers. You can change the port for security reasons or if another application uses it. Component Default port To change the default port: QA Wizard Pro Server to global application repository and status tool 8002 In ...
QA Wizard Pro 611 Error When Testing Applications Using Microsoft Active Accessibility
Problem The following error is returned when recording QA Wizard Pro scripts or populating the application repository for applications that use Microsoft Active Accessibility: 'Error communicating with the target application: [611].' Cause A known Visual Basic 6 issue occurs when an application ...
QtCoreSeapineTT4.dll Error When Starting QA Wizard Pro
Note: The following information only applies to QA Wizard Pro 2011.1.x and TestTrack 2011.1.x. Problem After upgrading to QA Wizard Pro and TestTrack 2011.1.x, the following error is displayed when starting QA Wizard Pro: 'Program cannot start because QtCoreSeapineTT4.dll on the computer gave er ...
QA Wizard Pro RDBMS Support
The QA Wizard Pro Server database can be stored in a Relational Database Management System (RDBMS) instead of the native format. Following are the supported database vendors and versions for the current version of QA Wizard Pro. Refer to 'Setting Up RDBMS Databases' in the QA Wizard Pro User Gui ...
QA Wizard Pro Global Repository Service Does Not Start
Problem The following error is returned when starting the QA Wizard Pro global repository service (QAWRepository.exe or QAWServer.exe) on Windows Server 2003 or Windows Server 2008: 'Error 1053: The service did not respond to the start or control request in a timely fashion' Cause The Windows se ...
Changing the Global Repository Data Directory and Port Number
Note: This information only applies to QA Wizard Pro 2011.0 and earlier. By default, the QA Wizard Pro application repository data is saved in [drive]:\QAWRepository, where [drive] is the drive letter of the installation path. For example, if you installed the product in C:\Program Files\Seapin ...
Silverlight Applications Stop Responding in Internet Explorer When Recording or Running QA Wizard Pro Scripts
Problem Recording or running scripts in QA Wizard Pro stops when testing Silverlight applications using Internet Explorer and one of the following errors is returned: ‘The target application is not responding.’ or ‘Error communicating with the target application.’ Cause ...
Silverlight Applications Crash in Firefox When Recording or Running QA Wizard Pro Scripts
Problem When recording or running QA Wizard Pro scripts, Microsoft Silverlight applications running in Mozilla Firefox 3.6.4 or later crash when a message box is displayed. Cause Using the MessageBox.Show method to display Silverlight message boxes causes Firefox to become unresponsive or plugin ...
Text Data is not Imported from Excel Files to QA Wizard Pro Datasheets
Problem Text data from a Microsoft Excel file is not imported to a QA Wizard Pro datasheet if the first eight rows under the column headers contain only numeric values. Cause The Excel ODBC driver uses the first eight rows in the file to determine each column’s data type. The data type use ...
Scripts That Test WPF Controls Fail After Upgrading to QA Wizard Pro 2010.1.1
Problem Scripts that test Windows Presentation Foundation (WPF) controls fail after upgrading to QA Wizard Pro 2010.1.1. Cause The Logical Address By Automation Id and Logical Address By Index control properties were not captured during recording and do not contain values. QA Wizard Pro cannot i ...
OpenRecordsetQuery Functions Using SQL Queries with Single Quotes Do Not Work
Problem Using the OpenRecordsetQuery function with a SQL query argument that contains single quotes does not work and a syntax error is returned. Cause SQL queries require single quotation marks with a Unicode value of 0096 (decimal). The single quote characters used in the QA Wizard Pro script ...
Select Statement Does Not Work As Expected When Retrieving Numeric Values from Local Datasheets
Problem When the Select statement is used to retrieve numeric values from a local datasheet, one of the following issues occurs: An incorrect value is returned from the datasheet. Playback fails and the following error is returned: The item cannot be found. Cause The Select statement treats ...
(Page 1 of 5)
«« |
Prev |
1 |
2 |
3 |
4 |
5 |
Next |
»»
|